- Compact size
- Built-in overheat protection
- Long service life
- DIN rail mountable
The compact HGL 046 fan heater prevents formation of condensation. The integrated high performance axial fan provides forced air circulation and so guarantees an even temperature in enclosures. The heater is wired using the internal terminal connectors.
Heating element | resistance - micanite |
---|---|
Overheat protection | built-in temperature limiter |
Heater body | extruded aluminum, anodized |
Surface temperature | 400 W heater - max. 167 °F (75 °C) |
Axial fan, ball bearing | service life 50,000 h at 77 °F (25 °C) |
Air flow, free blowing | AC: 26 cfm (45 m³/h) - 50 Hz; 32 cfm (54 m³/h) - 60 Hz DC: 32 cfm (54 m³/h) |
Connection | 3-pole terminal AWG 16 max. (1.5 mm²) with strain relief, clamping torque 0.8 Nm max. |
Connection housing | plastic, UL 94V-0, black |
Mounting | clip for 35 mm DIN rail, EN 60715 |
Mounting position | vertical |
Operating / Storage temperature | -49 to +158 °F (-45 to +70 °C) |
Operating / Storage humidity | max. 90 %RH (non-condensing) |
Protection class / Protection type | I (grounded) / IP20 |
Part No. | Heating capacity | Operating voltage | Recommended pre-fuse T (time-delay) | Length (L) | Weight (approx.) | Approvals | ||
---|---|---|---|---|---|---|---|---|
04640.0-00 | 250 W | AC 230 V, 50/60 Hz | 2.0 A | 7.2” (182 mm) | 2.4 lbs. (1.1 kg) | UL File No. E234324 | VDE | EAC |
04640.9-00 | 250 W | AC 120 V, 50/60 Hz | 4.0 A | 7.2” (182 mm) | 2.4 lbs. (1.1 kg) | UL File No. E234324 | VDE | EAC |
04641.0-00 | 400 W | AC 230 V, 50/60 Hz | 4.0 A | 8.7” (222 mm) | 3.1 lbs. (1.4 kg) | UL File No. E234324 | VDE | EAC |
04641.9-00 | 400 W | AC 120 V, 50/60 Hz | 6.3 A | 8.7” (222 mm) | 3.1 lbs. (1.4 kg) | UL File No. E234324 | VDE | EAC |

Pilot contact
e.g. KTO 011 Thermostat
Heater
Fan Heater HGL 046
(AC 120 V or AC 230 V)