Smart Sensor
CSS 014 | DC 24 V

#Stego #IoT #sensor #smart.factory #IO-Link

 

Interested in an Intelligent Condition Management system? Click on button to go to STEGO Connect.

 

 

  • Analog/digital interface
  • Compact size
  • Clip and/or screw mounting
  • High accuracy
  • Quick connection (M12 plug-in connector)
  • Wide temperature and humidity range
  • Various application areas (IEC 61010-1/DIN EN 61010-1)

The compact Smart Sensor CSS 014 electronically records temperature and humidity and converts the measured data into a standardized analog 4-20 mA or a digital IO-Link signal. The converted value signals can be utilized or further processed by a control or monitoring unit, e.g. a PLC control. The Smart Sensor is suitable for installation inside and outside the enclosure, even in harsh environmental conditions, such as wind power.

Technical Data

Download Technical Data Sheet

Download IO-Link Parameter Leaflet for Smart Sensor with IO-Link Interface

Download IODD for Smart Sensor CSS 014 with IO-Link Interface

Download IODD and all accompanying files, then import IODD file into your control software. Or go to the official IODDfinder by IO-Link.

Measuring signals
analog (4-20 mA)/digital (IO-Link)
digital (IO-Link)

temperature, humidity
events, diagnosis, device data
Max. reaction time3 min.
Load resistance (external)≤ 500 Ω (4-20 mA only)
ConnectionM12 round plug connector, IEC 61076-2-101, 4-pin, A-coded, shielded
Electrical protectionReverse-polarity, short circuit, overvoltage protection
Mountingclip for 35 mm DIN rail, EN 60715 and screw fixing M5
Casingplastic according to UL94 V-0, light grey
Dimensions140 x 40 x 38 mm
Weightapprox. 50 g
Fitting positionvertical (connection on top)
Storage temperature-40 to +85 °C (-40 to +185 °F)
Operating/Storage humiditymax. 90% RH (non-condensing)
Protection type1/Protection classIP20 (sensor only IP57) / III (SELV)
ApprovalsVDE and UL File No. E500143 (acc. to IEC 61010-1/DIN EN 61010-1)
NoteOther measuring ranges on request

¹ The PCB (printed circuit board) is coated on both sides with a certified protective lacquer to protect against corrosion and for improvement of the tracking resistance.

Art. No.InterfaceOperating voltagePower
consumption max.
Temperature
measuring range
Humidity
measuring range
Operating
temperature
Operating Instructions
01420.2-004-20 mA (analog)DC 24 V
(DC 12-30 V)
1.8 W
(typically 0.4 W)
40 to +60 °C
(-40 to +144 °F)
± 1 K
0 to 100 % RH
± 4%2
-40 to +70 °C
(-40 to +158 °F)
Download
01411.2-00
Download IODD
IO-Link (digital,
specified acc. to version 1.1)
DC 24 V
(DC 18-30 V)
0.3 W-40 to +80 °C
(-40 to +176 °F)
± 0.3 K
0 to 100% RH
± 3%2

-40 to +80 °C
(-40 to +176 °F)

Download

Download IODD and all accompanying files. Then import IODD file into your control software.

2 Tolerance within 20 to 80 % RH (please request diagram for tolerances outside this range)

Pin assignment

analog 4-20 mA (Art. No. 01420.2-00)
IO-Link (Art. No. 01411.2-00)

Example of Connection

Technical Drawing

(sensor only IP57)